Technical Parameters

Explosion-proof gradeExd II CT4Gb
电源DC24V, AC110V, AC220V, AC380V
标准力矩/时间600Nm/45S
回转角度范围0~90°可调
电机功率/电流DC24V: 70W/8.0A
AC110V: 90W/1.18A
AC220V: 90W/0.67A
AC380V: 40W /0.29A
可选控制电路A型/B型/C型/D型/E型/F型/G型/H型
整机重量10.0kg
绝缘电阻DC24V: 100MΩ/250VDC
AC110V/AC220V/AC380V: 100MΩ/500VDC
耐压等级DC24V/AC24V: 500VAC 1分钟
AC110V/AC220V:1500VAC 1分钟
AC380V:1800VAC 1分钟
protection classIP68
安装方法360°任意角度安装
电气接口2-M20x1.5防爆堵头,使用时用户应根据所选电缆,加装相应的防爆电缆接头
环境温度-20℃~+60℃
选装功能除湿加热器
调节型 控制参数
输入信号4~20mA, 0~10V任意标定
output signal4~20mA, 0~10V任意标定
computer bus485/Modbus/CAN
物联网WIFI/LoRA/4G
基本误差≤±1%
回差≤1%
死区0.5%~5.0%可调
阻尼特性0次
机构重复性误差≤1%

Mounting Dimensions

Huayi Explosion-Proof Actuator Installation Demension | DCL Explosion-Proof Actuator Installation Demension
Huayi Explosion-proof Actuator DCL-Ex40 DCL-Ex60 External Mounting Dimensions

control circuit

regulating type

Type E: with servo controller (regulated)

Input: 4~20mA / 0~10V Any configuration.

Output: 4~20mA / 0~10V Any configuration.

Bus: Modbus / CAN

Internet of Things: WIFI/LoRA/4G DTU

 

接线端子说明:
1、“电源”输入端的“N”接中线,“L”接 相线 ;
2、“输入信号”端的“-”接输人信号的负 极,“+”接输入信号的正极;
3、“输出信号”端的“-”接直流电流表的 负极,“+”接直流电流表的正极。

feedback-based

F 型 :带位置发送器

输出4~20mADC 阀 位信号(对阀位实 行全程反馈)。

 

接线端子说明:
1、“电源”输入端的“N”接中线,“L”接相线;
2、“电源”输入端的相线“L”接“关”时,向关 方向运行,接“开”时,向开方向运行;
3、“输出信号”端的“-”接直流电流表的负极, “+”接直流电流表的正极。

Type C: with 1KΩ (or 500Ω) potentiometer

通过开关电路实现 “开”、“关”操 作,并输出与开度 位置相对应的电阻 量信号。

 

接线端子说明:
1、端子1接电源中线;
2、电源相线与端子2接通时为“关”运行;
3、电源相线与端子3接通时为“开”运行;
4、端子4为电位器低端,“开”运行时,端子 4与端子5之间阻值随着开度的增大而增大;
5、端子5为电位器动臂;
6、端子6为电位器高端,“开”运行时,端子 6与端子5之间阻值随着开度的增大而减小;
7、端子7接地线。

D 型 :带电位器和无源触点位置开关

通过开关电路实现“开”、 “关”操作,并输出与开 度位置相对应的电阻量信 号,同时输出一组全开和 全关无源信号。

 

接线端子说明:
1、端子1接电源中线;
2、电源相线与端子2接通时为“关”运行;
3、电源相线与端子3接通时为“开”运行;
4、端子4为无源触点公共端;
5、“开”运行到位时,端子5输出“全开信号”;
6、“关”运行到位时,端子6输出“全关信号”;
7、端子7为电位器低端,“开”运行时,端子7与端子8之 间阻值随着开度的增大而增大;
8、端子8为电位器动臂;
9、端子9为定位器高端,“开”运行时,端子9与端子8之 间阻值随着开度的增大而减小;
10、端子12接地线。

switching type

Type A: with limit position switches (active contacts)

Through the switching circuit to realize the "on", "off" operation, and output a set of full open and full closed active signal.

 

接线端子说明:
1、端子1接电源中线;
2、电源相线与端子2接通时为“关”运行;
3、电源相线与端子3接通时为“开”运行;
4、电源相线与端子2接通且“关”运行到位时, 端子4所接“全关信号”指示灯亮;
5、电源相线与端子3接通且“开”运行到位时, 端子5所接“全开信号”指示灯亮;
6、端子7接地线。

Type B: with intermediate position switch (passive contact)

Through the switching circuit to realize the "on", "off" operation, and output a set of full open and full closed passive signal.

 

接线端子说明:
1、端子1接电源中线;
2、电源相线与端子2接通时为“关”运行;
3、电源相线与端子3接通时为“开”运行;
4、端子4为无源触点公共端;
5、“开”运行到位时,端子5输出“全开信号”;
6、“关”运行到位时,端子6输出“全关信号”;
7、端子7接地线。

Type G: DC control circuit with passive contact switches

According to the unidirectional conductivity of the diode, by reversing the positive and negative poles of the DC power supply, it realizes the "on" and "off" operation and outputs a set of passive signals of full on and full off.

 

接线端子说明:
1、端子1接电源正极,端子2接电源负极时为 “关”运行;端子2接电源正极,端子1接 电源负极时为“开”运行;
2、端子3为无源触点公共端;
3、“开”运行到位时,端子4输出“全开信号”;
4、“关”运行到位时,端子5输出“全关信号”;
5. Terminal 7 Ground wire.

H 型 :三相交流控制电路,带无源触点开关

通过外部倒相电路, 使电机正反转,从 而实现“开”、“关” 操作并输出一组全 开和全关无源信号。

 

接线端子说明:
1、端子1、2、3接三相交流电,通过外部倒相电路 实现电机正反转 ;
2、端子4为外部控制电路公共端;
3、端子5为“关”运行控制;
4、端子6为“开”运行控制;
5、端子7为无源触点公共端;
6、“开”运行到位时,端子8输出“全开信号”;
7、“关”运行到位时,端子9输出“全关信号”;
8、端子12接地线。

Notes:

  • 控制电路中虚线框内为执行机构内部电路,虚线框外电路仅供用户接线参考。
  • 如需定制控制电路,请联系技术支持。

查看其它型号​

Huayi Explosion-proof Series Actuator DCL-Ex05
DCL-Ex05
Huayi Explosion-proof Series Actuator DCL-Ex10 DCL-Ex20
DCL-Ex10
Huayi Explosion-proof Series Actuator DCL-Ex10 DCL-Ex20
DCL-Ex20
Huayi DCL-Ex40 Huayi DCL-Ex60
DCL-Ex40
Huayi DCL-Ex40 Huayi DCL-Ex60
DCL-Ex60
en_USEnglish

telephones

(+86) 130 2633 1611

DCL Wechat QR Code | Wechat QR Code

microsoft

Chen Gong - DCL