Selection table

型号rotation angleTorque/TimeType of controlSupply VoltageInput/Output SignalOptional Features
DCL-Ex050-360°可调50Nm/20S
selectable
20Nm/4S
30Nm/10S
50Nm/60S
switching type
regulating type
DC24V
AC24V
AC110V
AC220V
AC380V
4~20mA
0~10V
Level | Contacts
Modbus-RTU | CAN | Ethernet
Over-torque protection
Power failure reset
Self-heating dehumidification
自诊断和数据记录
DCL-Ex100-90°可调100Nm/30S
selectable
50Nm/15S
100Nm/60S
switching type
regulating type
DC24V
AC24V
AC110V
AC220V
AC380V
4~20mA
0~10V
Level | Contacts
Modbus-RTU | CAN | Ethernet
Over-torque protection
Power failure reset
Self-heating dehumidification
自诊断和数据记录
DCL-Ex200-90°可调200Nm/30S
selectable
100Nm/15S
200Nm/60S
switching type
regulating type
DC24V
AC110V
AC220V
AC380V
4~20mA
0~10V
Level | Contacts
Modbus-RTU | CAN | Ethernet
Over-torque protection
Power failure reset
Self-heating dehumidification
自诊断和数据记录
DCL-Ex400-90°可调400Nm/30S
selectable
200Nm/15S
400Nm/60S
switching type
regulating type
DC24V
AC110V
AC220V
AC380V
4~20mA
0~10V
Level | Contacts
Modbus-RTU | CAN | Ethernet
Over-torque protection
Power failure reset
Self-heating dehumidification
自诊断和数据记录
DCL-Ex600-90°可调600Nm/45S
selectable
switching type
regulating type
DC24V
AC110V
AC220V
AC380V
4~20mA
0~10V
Level | Contacts
Modbus-RTU | CAN | Ethernet
Over-torque protection
Power failure reset
Self-heating dehumidification
自诊断和数据记录

Valve Selection Recommendation Table

执行器型号蝶阀≤PNI1.0MPa球阀≤PN1.6MPa通风阀≤PN0.1MPa
DCL-Ex05DN50-60DN40DN50-80
DCL-Ex10DN80-100DN50-65DN100-200
DCL-Ex20DN125-150DN80-100DN250-300
DCL-Ex40DN200DN125DN350-450
DCL-Ex60DN250DN150DN500-600

Note: The matching data of actuator and valve in the table is for reference only, the specific torque value provided by the valve manufacturer shall prevail.

Because of the many types of valves, even if the same specifications of the valve, due to the manufacturer's manufacturing process, quality level, structural form, the valve body material is different, the torque value is different. And in actual use, often because of the system pressure fluctuations, media type, site environment, 'operating characteristics of different factors will also lead to the valve opening torque has a great change. In order to ensure the stable and reliable operation of the actuator, it is necessary to leave sufficient margin in the selection. It is recommended to leave a margin coefficient of times in the selection, i.e.: margin coefficient = actuator output torque / valve pressure test torque N1.1 ~ 1.3 times.

View the technical specifications of the different models

Huayi Explosion-proof Series Actuator DCL-Ex05
DCL-Ex05
Huayi Explosion-proof Series Actuator DCL-Ex10 DCL-Ex20
DCL-Ex10
Huayi Explosion-proof Series Actuator DCL-Ex10 DCL-Ex20
DCL-Ex20
Huayi DCL-Ex40 Huayi DCL-Ex60
DCL-Ex40
Huayi DCL-Ex40 Huayi DCL-Ex60
DCL-Ex60
en_USEnglish

Technical Consultation

DCL Wechat QR Code | Wechat QR Code

microsoft

扫描二维码咨询其它问题...

产品询价

点击“发送”,稍后我们将与您确认产品型号并向您发出报价单。
DCL Wechat QR Code | Wechat QR Code

microsoft

扫描二维码咨询其它问题...

telephones

(+86) 130 2633 1611

DCL Wechat QR Code | Wechat QR Code

microsoft

Chen Gong - DCL