{"id":5363,"date":"2023-05-31T13:47:30","date_gmt":"2023-05-31T05:47:30","guid":{"rendered":"http:\/\/www.dcl-controls.com\/?p=5363"},"modified":"2023-05-31T13:47:30","modified_gmt":"2023-05-31T05:47:30","slug":"setting-switch-actuator","status":"publish","type":"post","link":"https:\/\/dcl-actuator.com\/en_us\/2023\/05\/31\/setting-switch-actuator\/","title":{"rendered":"How to configure a switching actuator with bit-firing function?"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"5363\" class=\"elementor elementor-5363\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-9d3f5d6 elementor-section-full_width elementor-section-height-default elementor-section-height-default\" data-id=\"9d3f5d6\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-cc56700\" data-id=\"cc56700\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-24e61c6 elementor-widget elementor-widget-text-editor\" data-id=\"24e61c6\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li><a href=\"#step1\"><span style=\"text-decoration: underline;\">Mechanical Installation<\/span><\/a><\/li><li><a href=\"#step2\"><span style=\"text-decoration: underline;\">Position transmitter panel description<\/span><\/a><\/li><li><a href=\"#step3\"><span style=\"text-decoration: underline;\">Debugging and Setup<\/span><\/a><\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-583b268 elementor-widget elementor-widget-heading\" data-id=\"583b268\" data-element_type=\"widget\" id=\"step1\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">1. Mechanical installation<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-be92113 elementor-widget elementor-widget-text-editor\" data-id=\"be92113\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul>\n<li>refer to (another document) <a href=\"\/en_us\/faq\/actuator\/how-to-install-a-actuator-on-a-valve\/\">How to mount an actuator to a valve<\/a>If the actuator is mounted correctly on the valve body and operated manually, check for proper operation.<\/li>\n<li>\n<p>refer to (another document)<a href=\"\/en_us\/faq\/actuator\/how-to-set-up-a-electric-switch-type-actuator-valve\/\"> How to set the switching type electric valve<\/a>The electrical (CLS, OLS) and mechanical limits of the electric actuator are correctly adjusted.<\/p>\n<\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-eb7186b elementor-widget elementor-widget-text-editor\" data-id=\"eb7186b\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Special Tip:<\/p>\n<ul>\n<li>If there is no special requirement, the actuator travel angle between the fully closed position and fully open position is 90\u00b0 during factory commissioning. The corresponding output current is 4mA for fully closed position and 20mA for fully open position.<\/li>\n<li>The opening potentiometer has taken into account the possibility of shifting the potentiometer's working area due to changes in the fully closed and fully open positions during valve commissioning, so user adjustment of the potentiometer and potentiometer gear is generally prohibited.<\/li>\n<li>The terminal wiring should be connected correctly according to the following diagram.<\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bff35e6 elementor-widget elementor-widget-heading\" data-id=\"bff35e6\" data-element_type=\"widget\" id=\"step2\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">2\u3001Position sender panel description<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-198ff2d elementor-widget elementor-widget-image\" data-id=\"198ff2d\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"800\" height=\"797\" src=\"https:\/\/dcl-actuator.com\/wp-content\/uploads\/2023\/05\/position-feedback-setting.webp\" class=\"attachment-full size-full wp-image-5365\" alt=\"How to set up Wuhan Huayi Hair Actuator\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2aab9a9 elementor-widget elementor-widget-text-editor\" data-id=\"2aab9a9\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ol><li>Adjustable potentiometer:<ul><li>The \"full position\" and \"zero position\" are used to adjust the corresponding output current to 20mA or 4mA when the valve is fully open or fully closed.<\/li><\/ul><\/li><li>Indicator light:<ul><li>L1: Red, power indicator, illuminates when the bit generator is connected to power;<\/li><li>L2: Green, lighted when valve is open for operation;<\/li><li>L3: Green, lighted when valve is closed for operation;<\/li><\/ul><\/li><\/ol>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8e4bc95 elementor-widget elementor-widget-heading\" data-id=\"8e4bc95\" data-element_type=\"widget\" id=\"step3\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">3, debugging and setup<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-671e7a0 elementor-widget elementor-widget-text-editor\" data-id=\"671e7a0\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ol><li>Potentiometer center position determination<\/li><li>Output Current Correction<ul><li>The position generator has been calibrated at the factory and generally does not need to be adjusted by the user. If the output current is not 20mA or 4mA when the valve is fully open or fully closed, and the error is greater than 1%, then it needs to be adjusted, and can be corrected as follows: Connect a 20mADC ammeter to the output signal terminal, fully close the valve, adjust the \"zero\" potentiometer with a small screwdriver, and observe the ammeter display, and when the output is greater than 4mA, slowly rotate clockwise, and vice versa, slowly rotate counterclockwise until the ammeter displays 4mA (). When the output is greater than 4mA clockwise direction slowly rotate, and vice versa, then counterclockwise direction slowly rotate until the ammeter shows 4mA ( \u00b1 0.02); the valve is fully open, with a small screwdriver to adjust the \"full position\" potentiometer, observe the ammeter display, when the output is greater than 20mA counterclockwise direction slowly rotate, and vice versa, then clockwise direction slowly rotate, and the ammeter display, when the output is greater than 20mA, then clockwise direction slowly rotate, then clockwise direction slowly rotate, then clockwise direction slowly rotate, then clockwise direction slowly rotate. When the output is greater than 20mA, rotate slowly in counterclockwise direction, and vice versa, rotate slowly in clockwise direction until the ammeter shows 20mA (\u00b10.02), and the output current correction is completed.<\/li><\/ul><\/li><\/ol>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4ed6a17 elementor-widget elementor-widget-text-editor\" data-id=\"4ed6a17\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Note: The output current correction must be adjusted to the \"zero position\" first and then to the \"full position\", otherwise it will cause the position generator to malfunction.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<section class=\"elementor-section elementor-inner-section elementor-element elementor-element-8fc9a0d elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"8fc9a0d\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-c131ee3\" data-id=\"c131ee3\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-8d1612e elementor-widget elementor-widget-heading\" data-id=\"8d1612e\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\"><a href=\"\/en_us\/tech\/set-up-dcl-valve\/\">Previous\uff1aHow to set the switch type electric valve?<\/a><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-a2d79e0\" data-id=\"a2d79e0\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-a3ffde8 elementor-widget elementor-widget-heading\" data-id=\"a3ffde8\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\"><a href=\"\/en_us\/tech\/set-up-dcl-actuator\/\">Next\uff1aHow to set the regulation type electric valve?<\/a><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Mechanical Installation Position Sender Panel Description Commissioning and Setup 1. Mechanical Installation Refer to How to Mount the Actuator to the Valve to install the electric actuator correctly [...].<\/p>","protected":false},"author":1,"featured_media":5366,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"elementor_theme","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[8],"tags":[50,51,52,53,56,57,66],"class_list":["post-5363","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-tech","tag-on-off-actuator","tag-on-off-actuator-fb","tag-fast-move-actuator","tag-actuator","tag-user-manual","tag-general-actuator","tag-explosion-proof-actuator"],"acf":[],"_links":{"self":[{"href":"https:\/\/dcl-actuator.com\/en_us\/wp-json\/wp\/v2\/posts\/5363","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/dcl-actuator.com\/en_us\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/dcl-actuator.com\/en_us\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/dcl-actuator.com\/en_us\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/dcl-actuator.com\/en_us\/wp-json\/wp\/v2\/comments?post=5363"}],"version-history":[{"count":0,"href":"https:\/\/dcl-actuator.com\/en_us\/wp-json\/wp\/v2\/posts\/5363\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/dcl-actuator.com\/en_us\/wp-json\/wp\/v2\/media\/5366"}],"wp:attachment":[{"href":"https:\/\/dcl-actuator.com\/en_us\/wp-json\/wp\/v2\/media?parent=5363"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/dcl-actuator.com\/en_us\/wp-json\/wp\/v2\/categories?post=5363"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/dcl-actuator.com\/en_us\/wp-json\/wp\/v2\/tags?post=5363"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}