{"id":6032,"date":"2023-08-03T20:13:29","date_gmt":"2023-08-03T12:13:29","guid":{"rendered":"https:\/\/www.dcl-controls.com\/?p=6032"},"modified":"2023-08-03T20:13:29","modified_gmt":"2023-08-03T12:13:29","slug":"switch-actuator","status":"publish","type":"post","link":"https:\/\/dcl-actuator.com\/en_us\/2023\/08\/03\/switch-actuator\/","title":{"rendered":"Switching actuator common faults and troubleshooting"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"6032\" class=\"elementor elementor-6032\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-fe621b5 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"fe621b5\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-a1fea6d\" data-id=\"a1fea6d\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-49fc89d elementor-widget elementor-widget-text-editor\" data-id=\"49fc89d\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>This guide applies to DCL explosion-proof series\/general series\/quick-open series switching actuators with the following model numbers:<\/p><ul><li>General Series: DCL-05\/DCL-10\/DCL-20\/DCL-40\/DCL-60\/DCL-100\/DCL-160\/DCL-250<\/li><li>Explosion-proof Series: DCL-Ex05\/DCL-Ex10\/DCL-Ex20\/DCL-Ex40\/DCL-Ex60<\/li><li>Quick Open Series: DCL-K05\/DCL-K10\/DCL-K20\/DCL-K40\/DCL-K100<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e165a97 elementor-widget elementor-widget-heading\" data-id=\"e165a97\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">1, common faults and troubleshooting methods.<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0e767e9 elementor-widget elementor-widget-shortcode\" data-id=\"0e767e9\" data-element_type=\"widget\" data-widget_type=\"shortcode.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-shortcode\">\n<table id=\"tablepress-31\" class=\"tablepress tablepress-id-31 tbody-has-connected-cells\">\n<thead>\n<tr class=\"row-1\">\n\t<th class=\"column-1\">\u6545\u969c<\/th><th class=\"column-2\">\u53ef\u80fd\u7684\u539f\u56e0<\/th><th class=\"column-3\">\u6392\u9664\u65b9\u6cd5<\/th>\n<\/tr>\n<\/thead>\n<tbody class=\"row-striping row-hover\">\n<tr class=\"row-2\">\n\t<td rowspan=\"5\" class=\"column-1\">\u6267\u884c\u5668\u5728\u521d\u6b21\u542f\u52a8\u65f6\u4e0d\u4f1a\u6253\u5f00\u6216\u5173\u95ed<\/td><td class=\"column-2\">1. \u63a5\u7ebf\u4e0d\u6b63\u786e<\/td><td class=\"column-3\">\u6309\u7167\u6267\u884c\u5668\u7684\u63a5\u7ebf\u56fe\u6838\u5bf9\u63a5\u7ebf\u662f\u5426\u6b63\u786e\uff1f<\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td class=\"column-2\">2. \u4f9b\u7535\u7535\u6e90\u4e0d\u6b63\u786e<\/td><td class=\"column-3\">\u786e\u8ba4\u4f9b\u7535\u7535\u6e90\u7684\u8f93\u51fa\u7535\u538b\u4e3a\u6267\u884c\u5668\u989d\u5b9a\u7535\u538b\u7684\u00b110%\uff0c\u8f93\u51fa\u7535\u6d41\u4e3a\u6267\u884c\u5668\u989d\u5b9a\u7535\u6d41\u76843\u500d\u3002<\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td class=\"column-2\">3. \u63a7\u5236\u5f00\u5173\u6216\u63a7\u5236\u7ee7\u7535\u5668\u5f02\u5e38<\/td><td class=\"column-3\">\u4f7f\u7528\u4e07\u7528\u8868\u6d4b\u91cf\u6267\u884c\u5668\u5f00\u5173\u63a7\u5236\u7aef\u7684\u8f93\u5165\u7535\u538b\uff0c\u786e\u8ba4\u662f\u5426\u7b26\u5408\u9884\u671f\uff1f<\/td>\n<\/tr>\n<tr class=\"row-5\">\n\t<td class=\"column-2\">4. \u63a7\u5236\u7cfb\u7edf\u5339\u914d\u95ee\u9898<\/td><td class=\"column-3\">\u4f7f\u7528\u673a\u68b0\u5f00\u5173\u6d4b\u91cf\u6267\u884c\u5668\u529f\u80fd\uff0c\u5982\u679c\u6267\u884c\u5668\u8fd0\u884c\u6b63\u5e38\uff0c\u6838\u5bf9\u63a7\u5236\u7cfb\u7edf\u7684\u8f93\u51fa\u903b\u8f91\u662f\u5426\u7b26\u5408\u9884\u671f\uff1f<\/td>\n<\/tr>\n<tr class=\"row-6\">\n\t<td class=\"column-2\">5. \u591a\u4e2a\u6267\u884c\u5668\u6216\u6267\u884c\u5668\u548c\u5176\u5b83\u8bbe\u5907\u5e76\u8054<\/td><td class=\"column-3\">\u5f00\u5173\u578b\u6267\u884c\u5668\u662f\u901a\u8fc7\u542f\u52a8\u7535\u5bb9\u5b8c\u6210\u542f\u52a8\u7684\uff0c\u548c\u5176\u5b83\u8bbe\u5907\u5e76\u8054\u5c06\u5bf9\u542f\u52a8\u7535\u5bb9\u7684\u5bb9\u503c\u4ea7\u751f\u5f71\u54cd\u3002\u6240\u4ee5\uff0c\u5f00\u5173\u578b\u6267\u884c\u5668\u53ea\u80fd\u4f7f\u7528\u5355\u8def\u63a7\u5236\uff0c\u4e0d\u80fd\u5e76\u8054\u3002<\/td>\n<\/tr>\n<tr class=\"row-7\">\n\t<td rowspan=\"2\" class=\"column-1\">\u6267\u884c\u5668\u53ea\u80fd\u5f00\u542f\u6216\u5173\u95ed<\/td><td class=\"column-2\">1. \u63a5\u7ebf\u4e0d\u6b63\u786e<\/td><td class=\"column-3\">1. \u4f7f\u7528\u673a\u68b0\u5f00\u5173\u6d4b\u91cf\u6267\u884c\u5668\u529f\u80fd\uff0c\u5982\u679c\u6267\u884c\u5668\u8fd0\u884c\u6b63\u5e38\uff0c\u6838\u5bf9\u63a7\u5236\u7cfb\u7edf\u7684\u8f93\u51fa\u903b\u8f91\u662f\u5426\u7b26\u5408\u9884\u671f\uff1f<br \/>\n2. \u6309\u7167\u6267\u884c\u5668\u7684\u63a5\u7ebf\u56fe\u6838\u5bf9\u63a5\u7ebf\u662f\u5426\u6b63\u786e\uff1f<br \/>\n<\/td>\n<\/tr>\n<tr class=\"row-8\">\n\t<td class=\"column-2\">2. \u5168\u5f00\/\u5168\u5173 \u51f8\u8f6e\u8bbe\u7f6e\u4e0d\u5f53<\/td><td class=\"column-3\">refer to (another document)<a href=\"\/en_us\/faq\/actuator\/set-up-dcl-valve\/\">\u300a\u5982\u4f55\u8bbe\u7f6e\u5f00\u5173\u578b\u7535\u52a8\u9600\u95e8\u300b<\/a>\uff0c\u6b63\u786e\u8bbe\u7f6e\u51f8\u8f6e\u4f4d\u7f6e\u3002<\/td>\n<\/tr>\n<tr class=\"row-9\">\n\t<td rowspan=\"3\" class=\"column-1\">\u6267\u884c\u5668\u5728\u884c\u7a0b\u4e2d\u95f4\u505c\u6b62<\/td><td class=\"column-2\">1. \u9600\u95e8\u5361\u6ede<\/td><td class=\"column-3\">\u68c0\u67e5\u9600\u95e8\u662f\u5426\u5b58\u5728\u5361\u6ede\uff0c\u6d88\u9664\u5361\u6ede\uff0c\u5e76\u5728\u6267\u884c\u5668\u8fc7\u8f7d\u4fdd\u62a4\u51b7\u5374\u540e\u91cd\u8bd5\u3002<\/td>\n<\/tr>\n<tr class=\"row-10\">\n\t<td class=\"column-2\">2. \u6d41\u4f53\u4ecb\u8d28\u4e2d\u6f5c\u5728\u7684\u56fa\u4f53\u7269\u5bfc\u81f4\u9600\u95e8\u5361\u6ede\u3002<\/td><td class=\"column-3\">\u68c0\u67e5\u6d41\u4f53\u4ecb\u8d28\u4e2d\u662f\u5426\u5b58\u5728\u56fa\u4f53\u7269\u5361\u6ede\u9600\u95e8\u7684\u60c5\u51b5\uff0c\u6d88\u9664\u9600\u95e8\u5361\u6ede\uff0c\u5e76\u5728\u6267\u884c\u5668\u8fc7\u8f7d\u4fdd\u62a4\u51b7\u5374\u540e\u91cd\u8bd5\u3002<\/td>\n<\/tr>\n<tr class=\"row-11\">\n\t<td class=\"column-2\">3. \u5168\u5f00\/\u5168\u5173 \u6321\u5757\u8bbe\u7f6e\u4e0d\u5f53<\/td><td class=\"column-3\">refer to (another document)<a href=\"\/en_us\/faq\/actuator\/set-up-dcl-valve\/\">\u300a\u5982\u4f55\u8bbe\u7f6e\u5f00\u5173\u578b\u7535\u52a8\u9600\u95e8\u300b<\/a>\uff0c\u6b63\u786e\u8bbe\u7f6e\u6321\u5757\u4f4d\u7f6e\u3002<\/td>\n<\/tr>\n<tr class=\"row-12\">\n\t<td rowspan=\"3\" class=\"column-1\">\u4f7f\u7528\u624b\u67c4\uff0c\u65e0\u6cd5\u8f6c\u52a8\u6267\u884c\u5668<\/td><td class=\"column-2\">1. \u6d41\u4f53\u4ecb\u8d28\u4e2d\u6f5c\u5728\u7684\u56fa\u4f53\u7269\u5bfc\u81f4\u9600\u95e8\u5361\u6b7b\u3002<\/td><td class=\"column-3\">\u68c0\u67e5\u6d41\u4f53\u4ecb\u8d28\u4e2d\u662f\u5426\u5b58\u5728\u56fa\u4f53\u7269\u5361\u6ede\u9600\u95e8\u7684\u60c5\u51b5\uff0c\u6d88\u9664\u9600\u95e8\u5361\u6ede\uff0c\u5e76\u5728\u6267\u884c\u5668\u8fc7\u8f7d\u4fdd\u62a4\u51b7\u5374\u540e\u91cd\u8bd5\u3002<\/td>\n<\/tr>\n<tr class=\"row-13\">\n\t<td class=\"column-2\">2. \u9600\u95e8\u5361\u6b7b<\/td><td class=\"column-3\">\u68c0\u67e5\u9600\u95e8\u662f\u5426\u5b58\u5728\u5361\u6ede\uff0c\u6d88\u9664\u5361\u6ede\uff0c\u5e76\u5728\u6267\u884c\u5668\u8fc7\u8f7d\u4fdd\u62a4\u51b7\u5374\u540e\u91cd\u8bd5\u3002<\/td>\n<\/tr>\n<tr class=\"row-14\">\n\t<td class=\"column-2\">3. \u6267\u884c\u5668\u51cf\u901f\u673a\u6784\u635f\u574f\u3002<\/td><td class=\"column-3\">\u4ece\u9600\u95e8\u4e0a\u62c6\u4e0b\u6267\u884c\u5668\uff0c\u8f6c\u52a8\u624b\u67c4\u3002\u5982\u679c\u4e0d\u80fd\u8f6c\u52a8\uff0c\u4f7f\u7528\u65b0\u7684\u6267\u884c\u5668\u66f4\u6362\u3002<\/td>\n<\/tr>\n<tr class=\"row-15\">\n\t<td rowspan=\"3\" class=\"column-1\">\u4f4d\u7f6e\u53cd\u9988\u4fe1\u53f7\u65e0\u8f93\u51fa<\/td><td class=\"column-2\">1. \u5f00\u5173\u63a5\u7ebf\u4e0d\u6b63\u786e<\/td><td class=\"column-3\">\u6309\u7167\u6267\u884c\u5668\u7684\u63a5\u7ebf\u56fe\u6838\u5bf9\u63a5\u7ebf\u662f\u5426\u6b63\u786e\uff1f<\/td>\n<\/tr>\n<tr class=\"row-16\">\n\t<td class=\"column-2\">2. \u5168\u5f00\/\u5168\u5173 \u51f8\u8f6e\u8bbe\u7f6e\u4e0d\u5f53<\/td><td class=\"column-3\">refer to (another document)<a href=\"\/en_us\/faq\/actuator\/set-up-dcl-valve\/\">\u300a\u5982\u4f55\u8bbe\u7f6e\u5f00\u5173\u578b\u7535\u52a8\u9600\u95e8\u300b<\/a>\uff0c\u6b63\u786e\u8bbe\u7f6e\u51f8\u8f6e\u4f4d\u7f6e\u3002<\/td>\n<\/tr>\n<tr class=\"row-17\">\n\t<td class=\"column-2\">3. \u8fc7\u6d41\u5bfc\u81f4\u4f4d\u7f6e\u53cd\u9988\u4fe1\u53f7\u5f00\u5173\u635f\u574f\u3002<\/td><td class=\"column-3\">1. \u53c2\u7167<a href=\"\/en_us\/faq\/actuator\/set-up-dcl-valve\/\">\u300a\u5982\u4f55\u8bbe\u7f6e\u5f00\u5173\u578b\u7535\u52a8\u9600\u95e8\u300b<\/a>\uff0c\u68c0\u67e5\u5168\u5f00\/\u5168\u5173 \u51f8\u8f6e\u662f\u5426\u538b\u5b9e\u4f4d\u7f6e\u53cd\u9988\u5f00\u5173\uff1f<br \/>\n2. \u6d4b\u91cf\u4f4d\u7f6e\u53cd\u9988\u56de\u8def\u662f\u5426\u63a5\u901a\uff1f<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-31 from cache --><\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-61551f6 elementor-widget elementor-widget-image\" data-id=\"61551f6\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"696\" height=\"600\" src=\"https:\/\/dcl-actuator.com\/wp-content\/uploads\/2023\/05\/dcl-actuator-product-line.webp\" class=\"attachment-full size-full wp-image-4829\" alt=\"DCL Actuators Product Line | DCL Actuators\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-80d621f elementor-widget elementor-widget-heading\" data-id=\"80d621f\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">2\u3001Please check whether the application working condition meets the parameter requirements.<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4c66d29 elementor-widget elementor-widget-text-editor\" data-id=\"4c66d29\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>\u00a0 \u00a0 \u00a0 Electric actuators can fail due to improper use or under the wrong application conditions. Long-term trouble-free operation of the actuator will be ensured under the application conditions defined in the product specification.<\/p><ul><li><strong>Supply voltage:<\/strong>The voltage of the power supply must be within the rated operating voltage of the actuator. Overvoltage or undervoltage may result in reduced actuator life.<\/li><li><span style=\"font-weight: bold;\">Supply current:<\/span>Since the starting current of the motor is much larger than the rated current. To ensure reliable operation of the actuator, use a power supply with an output current capacity more than three times the rated current of the actuator.<\/li><li><strong>Temperature:<\/strong>Ensure that the actuator operates within the rated operating temperature range. Use of the actuator in environments outside of the rated operating temperature range may result in malfunction or reduced service life of the actuator, and ultimately, failure of the actuator.<\/li><li><strong>Environment:<\/strong>DCL switching actuators have an IP67 weatherproof rating. Generally suitable for indoor or outdoor applications. Provides a degree of protection against rain and splashing water. Protecting the actuator from rain, snow, ice, and UV (sunlight) usually extends the life of the product. Very corrosive environments may cause premature failure of electronic equipment. Do not use non-explosion proof series actuators in explosion proof environments.<\/li><li><strong>Energized persistence rate:<\/strong>The DCL switching actuator has an energization duration rate of 70% (42 seconds of operation per minute and must be turned off for 18 seconds), exceeding the 70% energization duration rate will cause the motor to go into overheat protection.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cdce1cd elementor-widget elementor-widget-heading\" data-id=\"cdce1cd\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">3\u3001Check whether the wiring of the actuator is correct or not<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<section class=\"elementor-section elementor-inner-section elementor-element elementor-element-c4bef91 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"c4bef91\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-ec2666c\" data-id=\"ec2666c\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-7a9dfe7 elementor-widget elementor-widget-heading\" data-id=\"7a9dfe7\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Type A: with limit position switches (active contacts)<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d609f95 elementor-widget elementor-widget-image\" data-id=\"d609f95\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"400\" height=\"341\" src=\"https:\/\/dcl-actuator.com\/wp-content\/uploads\/2023\/05\/dcl-actuator-interface-diagram-a.webp\" class=\"attachment-full size-full wp-image-4860\" alt=\"DCL Hua Yi actuator A type interface diagram\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6bbe9b8 elementor-widget elementor-widget-text-editor\" data-id=\"6bbe9b8\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Through the switching circuit to realize the \"on\", \"off\" operation, and output a set of full open and full closed active signal.<\/p><p><strong>Wiring Instructions:<\/strong><br \/>1. Terminal 1 is connected to the center line of the power supply;<br \/>2\u3001 Power supply phase line and terminal 2 connected for \"off\" operation;<br \/>3. The power supply phase line is \"on\" when it is connected to terminal 3;<br \/>4, power supply phase line and terminal 2 connected and \"off\" operation in place, terminal 4 connected to the \"full off signal\" indicator light;<br \/>5, power supply phase line and terminal 3 connected and \"open\" operation in place, terminal 5 connected to the \"full open signal\" indicator light;<br \/>6. Terminal 7 Ground wire.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-920f58e\" data-id=\"920f58e\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-69964db elementor-widget elementor-widget-heading\" data-id=\"69964db\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Type B: with intermediate position switch (passive contact)<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-85c2186 elementor-widget elementor-widget-image\" data-id=\"85c2186\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"400\" height=\"348\" src=\"https:\/\/dcl-actuator.com\/wp-content\/uploads\/2023\/05\/dcl-actuator-interface-diagram-b.webp\" class=\"attachment-full size-full wp-image-4858\" alt=\"DCL Hua Yi actuator B type interface diagram\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1a9717e elementor-widget elementor-widget-text-editor\" data-id=\"1a9717e\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Through the switching circuit to realize the \"on\", \"off\" operation, and output a set of full open and full closed passive signal.<\/p><p><strong>Wiring Instructions:<\/strong><br \/>1. Terminal 1 is connected to the center line of the power supply;<br \/>2\u3001 Power supply phase line and terminal 2 connected for \"off\" operation;<br \/>3. The power supply phase line is \"on\" when it is connected to terminal 3;<br \/>4. Terminal 4 is the common terminal of passive contact;<br \/>5. When \"open\" operation is in place, terminal 5 outputs \"full open signal\".<br \/>6\u3001When the \"OFF\" operation is in place, the terminal will program the \"Full Off Signal\";<br \/>7. Terminal 7 ground wire.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-inner-section elementor-element elementor-element-3ebb697 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"3ebb697\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-3fdff56\" data-id=\"3fdff56\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-e449214 elementor-widget elementor-widget-heading\" data-id=\"e449214\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Type C: with 1K\u03a9 (or 500\u03a9) potentiometer<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c4b3915 elementor-widget elementor-widget-image\" data-id=\"c4b3915\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"380\" src=\"https:\/\/dcl-actuator.com\/wp-content\/uploads\/2023\/05\/dcl-actuator-interface-diagram-c.webp\" class=\"attachment-full size-full wp-image-4856\" alt=\"DCL Hua Yi actuator C type interface diagram\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f5aa67a elementor-widget elementor-widget-text-editor\" data-id=\"f5aa67a\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>The switching circuit realizes \"on\" and \"off\" operation and outputs a resistance signal corresponding to the opening position.<\/p><p><strong>Wiring Instructions:<\/strong><br \/>1. Terminal 1 is connected to the center line of the power supply;<br \/>2\u3001 Power supply phase line and terminal 2 connected for \"off\" operation;<br \/>3. The power supply phase line is \"on\" when it is connected to terminal 3;<br \/>Terminal 4 is the low end of the potentiometer, when \"open\" operation, the resistance between terminal 4 and terminal 5 increases with the increase of the opening degree;<br \/>5. Terminal 5 is the potentiometer movable arm;<br \/>Terminal 6 is the high end of the potentiometer, when \"open\" operation, the resistance between terminal 6 and terminal 5 decreases with the increase of the opening degree;<br \/>7. Terminal 7 ground wire.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-ad7634c\" data-id=\"ad7634c\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-4368662 elementor-widget elementor-widget-heading\" data-id=\"4368662\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Type D: with potentiometer and passive contact position switches<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c1941c4 elementor-widget elementor-widget-image\" data-id=\"c1941c4\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"437\" src=\"https:\/\/dcl-actuator.com\/wp-content\/uploads\/2023\/05\/dcl-actuator-interface-diagram-d.webp\" class=\"attachment-full size-full wp-image-4859\" alt=\"DCL Hua Yi actuator D-type interface diagram\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4aa2119 elementor-widget elementor-widget-text-editor\" data-id=\"4aa2119\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Through the switching circuit to realize the \"on\", \"off\" operation, and output and open position corresponding to the amount of resistance signals, while outputting a set of fully open and fully closed passive signals.<\/p><p><strong>Wiring Instructions:<\/strong><br \/>1. Terminal 1 is connected to the center line of the power supply;<br \/>2\u3001 Power supply phase line and terminal 2 connected for \"off\" operation;<br \/>3. The power supply phase line is \"on\" when it is connected to terminal 3;<br \/>4. Terminal 4 is the common terminal of passive contact;<br \/>5, \"open\" operation in place, terminal 5 output \"full open signal\";<br \/>6\u3001When the \"Off\" operation is in place, the \"Full Off Signal\" will come out from the terminal.<br \/>Terminal 7 is the low end of the potentiometer, when \"open\" operation, the resistance between terminal 7 and terminal 8 increases with the increase of the opening degree;<br \/>8. Terminal 8 is the potentiometer movable arm;<br \/>Terminal 9 is the high end of the positioner, when \"open\" operation, the resistance between terminal 9 and terminal 8 decreases with the increase of the opening degree;<br \/>10. Terminal 12 grounding wire.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-inner-section elementor-element elementor-element-986a256 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"986a256\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-1b4006e\" data-id=\"1b4006e\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-44c989d elementor-widget elementor-widget-heading\" data-id=\"44c989d\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Type F: with position transmitter<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-04d92ee elementor-widget elementor-widget-image\" data-id=\"04d92ee\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"316\" src=\"https:\/\/dcl-actuator.com\/wp-content\/uploads\/2023\/05\/dcl-actuator-interface-diagram-f.webp\" class=\"attachment-full size-full wp-image-4855\" alt=\"DCL Hua Yi actuator F-type interface diagram\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2249dac elementor-widget elementor-widget-text-editor\" data-id=\"2249dac\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Through the switching circuit to realize the \"on\", \"off\" operation, and output a set of full open and full closed active signal.<\/p>\n<p><strong>Wiring Instructions:<\/strong><br>1. \"N\" of the \"Power\" input is connected to the center line, and \"L\" is connected to the phase line.<br>2\u3001When the phase line \"L\" of the input of \"power supply\" is connected to \"off\", it will run in the direction of off, and when it is connected to \"on\", it will run in the direction of on. When \"L\" is connected to \"OFF\", it runs in the OFF direction;<br>3. The \"output signal\" end is connected to the negative pole of the DC ammeter, and the \"+\" is connected to the positive pole of the DC ammeter.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-fe3e435\" data-id=\"fe3e435\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-669c582 elementor-widget elementor-widget-heading\" data-id=\"669c582\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Type G: DC control circuit with passive contact switches<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-35d9b4b elementor-widget elementor-widget-image\" data-id=\"35d9b4b\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"391\" src=\"https:\/\/dcl-actuator.com\/wp-content\/uploads\/2023\/05\/dcl-actuator-interface-diagram-g.webp\" class=\"attachment-full size-full wp-image-4853\" alt=\"DCL Hua Yi actuator G type interface diagram\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-34dba4c elementor-widget elementor-widget-text-editor\" data-id=\"34dba4c\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>According to the unidirectional conductivity of the diode, by reversing the positive and negative poles of the DC power supply, it realizes the \"on\" and \"off\" operation and outputs a set of passive signals of full on and full off.<\/p><p><strong>Wiring Instructions:<\/strong><br \/>Terminal 1 is connected to the positive pole of the power supply, and terminal 2 is connected to the negative pole of the power supply for \"off\" operation; lemon 2 is connected to the positive pole of the power supply, and terminal 1 is connected to the negative pole of the power supply for \"on\" operation;<br \/>2\u3001 Terminal 3 is the common terminal of passive contact;<br \/>3. When the \"open\" operation is in place, the terminals confirm the \"full open signal\".<br \/>4\u3001When \"Off\" operation is in place, terminal 5 outputs \"full off signal\".<br \/>5. Terminal 7 Ground wire.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-inner-section elementor-element elementor-element-e3d71b9 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"e3d71b9\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-98695b9\" data-id=\"98695b9\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-30aff6d elementor-widget elementor-widget-heading\" data-id=\"30aff6d\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Type H: Three-phase AC control circuit with passive contact switches<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b4e9fe9 elementor-widget elementor-widget-image\" data-id=\"b4e9fe9\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"412\" src=\"https:\/\/dcl-actuator.com\/wp-content\/uploads\/2023\/05\/dcl-actuator-interface-diagram-h.webp\" class=\"attachment-full size-full wp-image-4854\" alt=\"DCL Hua Yi actuator H-type interface diagram\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cb8b4e9 elementor-widget elementor-widget-text-editor\" data-id=\"cb8b4e9\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Through the external phase inversion circuit, the motor is reversed to realize \"on\" and \"off\" operation and output a set of passive signals for full on and full off.<\/p><p><strong>Wiring Instructions:<\/strong><br \/>Terminals 1, 2 and 3 are connected to three-phase alternating current to realize forward and reverse rotation of the motor through external phase reversal circuit;<br \/>2. Terminal 4 is the common terminal of the external control circuit;<br \/>3. Terminal 5 is the \"off\" operation control;<br \/>4. Terminal 6 is \"on\" operation control;<br \/>5. Terminal 7 is the common terminal of passive contact;<br \/>6\u3001When the \"open\" operation is in place, the terminal Han out of the \"full open signal\".<br \/>7\u3001When \"OFF\" operation is in place, terminal 9 outputs \"full off signal\";<br \/>8. Terminal 12 ground wire.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-c0158b3\" data-id=\"c0158b3\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap\">\n\t\t\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>This guide is applicable to DCL explosion-proof series\/ordinary series\/quick-open series switching actuators, the models are as follows: Ordinary series: DCL-05\/DCL-10 [...].<\/p>","protected":false},"author":1,"featured_media":6913,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"elementor_theme","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[3],"tags":[48,50,52,53,57,66],"class_list":["post-6032","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-ts","tag-trouble-shooting-guide","tag-on-off-actuator","tag-fast-move-actuator","tag-actuator","tag-general-actuator","tag-explosion-proof-actuator"],"acf":[],"_links":{"self":[{"href":"https:\/\/dcl-actuator.com\/en_us\/wp-json\/wp\/v2\/posts\/6032","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/dcl-actuator.com\/en_us\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/dcl-actuator.com\/en_us\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/dcl-actuator.com\/en_us\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/dcl-actuator.com\/en_us\/wp-json\/wp\/v2\/comments?post=6032"}],"version-history":[{"count":0,"href":"https:\/\/dcl-actuator.com\/en_us\/wp-json\/wp\/v2\/posts\/6032\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/dcl-actuator.com\/en_us\/wp-json\/"}],"wp:attachment":[{"href":"https:\/\/dcl-actuator.com\/en_us\/wp-json\/wp\/v2\/media?parent=6032"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/dcl-actuator.com\/en_us\/wp-json\/wp\/v2\/categories?post=6032"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/dcl-actuator.com\/en_us\/wp-json\/wp\/v2\/tags?post=6032"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}